Power & Utilities

manufacturing delivery18 products
requirements · 18

What this sector arrives with

copynot yet written

A substation DC auxiliary supply that must not fail: tripping and closing supplies, protection, the alarm set, and increasingly a link to SCADA rather than an island. This buyer reads specifications — name the standard worked to.

categories serving this industry · 07counts are products serving this industry
Products for this industry · 18ratings are standard builds · pricing by enquiry
Cathodic Protection TR Unit — Air Cooled
Thyristor-controlled transformer rectifier for impressed-current corrosion protection of buried pipelines and tank farms, in a naturally ventilated enclosure.
0–75 VDC · 5–130 A
Cathodic Protection TR Unit — Oil Cooled
Oil-immersed transformer rectifier for high-duty and high-ambient cathodic protection sites where continuous full-load output is required.
0–75 VDC · 15–130 A
CP Electronic Control Retrofit
Drop-in replacement control and firing electronics for obsolete imported transformer rectifiers, reusing the existing tank and magnetics.
0-50 VDC 100 A
Automatic Plating Rectifier
Thyristor-controlled, closed-loop DC supply for electroplating lines — low-voltage, very high current, with optional periodic reverse.
0–60 VDC · 100–20,000 A
Grid Station Battery Charger — Type A (WAPDA P-133:95)
The standard 110 VDC / 220 VDC substation charger, built to WAPDA specification P-133:95 — the governing specification for grid-station DC supply in Pakistan.
110 VDC · 5–200 A
Telecom Battery Charger 48 VDC (1+1 Redundant)
Dual-module 48 VDC power system built to telecom specifications, with N+1 redundancy and load sharing from 30 A to 200 A.
1–415 VAC · 30–200 A
Industrial Battery Charger with HMI & SCADA
High-capacity 110-220 VDC charger with touch HMI, 4-20 mA transmitters and RS-485 Modbus for integration into plant SCADA.
110–220 VDC · 100–200 A
Battery Cell Charger 2-8 VDC
Low-voltage, high-capacity charger for individual 600 Ah cells during battery-bank commissioning and capacity restoration.
2 VDC and 8 VDC cell formats
Battery Banks, Stands & Fuse Boxes
Matched battery banks with stands, inter-cell links and fused isolation, supplied and commissioned with the charger.
110 VDC 400 Ah with battery fuse box
Relay-Controlled Voltage Stabiliser
Economical stepped-tap stabiliser, 300 VA to 8 kVA, with a very wide 90-280 VAC input window for weak distribution networks.
220 VAC regulated
Control Transformer
Auxiliary supply transformers for LT and HT switchgear panels, wound to panel-builder requirement.
Waterproof Low-Voltage Transformer
Sealed 6 / 12 / 24 / 36 / 48 VAC transformers for underwater lighting and wet-environment low-voltage supplies.
6 / 12 / 24 / 36 / 48 VAC
DC/AC Inverter Panel
Substation inverters converting the station 110/220 VDC battery bus to 230 VAC or 400 VAC 3-phase, 2-20 kVA.
2 kVA to 20 kVA
AC UPS & Parallel-Redundant UPS
Industrial UPS from 2 kVA to 15 kVA, including parallel-redundant configurations for SCADA and critical control.
2 kVA to 15 kVA
DC Distribution Board (DCDB)
Compartmentalised DC distribution boards with per-circuit MCBs, monitoring and earth-fault detection, up to 20 outgoing ways.
24 / 48 / 110 / 220 VDC
DC Earth Fault Relay
Adjustable 1-10 kΩ DC insulation monitoring relay with test button, for unearthed station DC systems.
24 / 48 / 110 / 220 VDC
Motor Starter Panel (Star-Delta / DOL)
Star-delta and direct-on-line motor starter panels with overload and phase protection, built to motor rating.
30 HP star-delta (built to motor rating)
System Monitoring Panel
PLC-based supervisory panel aggregating status, alarms and metering from chargers, inverters and distribution into one interface.
superseded
not listed

A rating outside these builds

Send the input supply, required output, enclosure rating and site ambient. We quote against the same platform as the listed builds.

Enquire
Industries