Telecom & Data

manufacturing delivery11 products
requirements · 11

What this sector arrives with

copynot yet written

A 48 VDC plant that has to survive a bad grid without a site visit — redundancy, low-voltage disconnect, remote alarms — or a wide-input stabiliser for equipment on a network that swings outside tolerance. Lead with the redundancy and monitoring architecture.

categories serving this industry · 05counts are products serving this industry
Products for this industry · 11ratings are standard builds · pricing by enquiry
Automatic Plating Rectifier
Thyristor-controlled, closed-loop DC supply for electroplating lines — low-voltage, very high current, with optional periodic reverse.
0–60 VDC · 100–20,000 A
Telecom Battery Charger 48 VDC (1+1 Redundant)
Dual-module 48 VDC power system built to telecom specifications, with N+1 redundancy and load sharing from 30 A to 200 A.
1–415 VAC · 30–200 A
Floating Battery Charger 24 VDC
Compact 24 VDC float charger, 20-70 A, for communications, signalling and vehicle-battery duty.
220 VAC · 20–70 A
Battery Banks, Stands & Fuse Boxes
Matched battery banks with stands, inter-cell links and fused isolation, supplied and commissioned with the charger.
110 VDC 400 Ah with battery fuse box
Servo-Controlled Automatic Voltage Regulator
Motorised-variac AVR from 500 VA to 300 kVA holding output within ±1-2% against a ±25% input swing, with no added waveform distortion.
380 VAC ±1% to ±2%, 3-phase; 220 VAC ±1-3%, 1-phase
IGBT-Controlled Static AVR
Transformerless-tap static regulator, 2-100 kVA, correcting to ±1% in milliseconds with no moving parts.
2-15 kVA single-phase; 5-100 kVA three-phase
Relay-Controlled Voltage Stabiliser
Economical stepped-tap stabiliser, 300 VA to 8 kVA, with a very wide 90-280 VAC input window for weak distribution networks.
220 VAC regulated
Harmonic Filter
Passive filter delivering a clean sine wave to sensitive electronic loads on distorted supplies.
400 VAC, 25 A
Step-Down Distribution Transformer
Dry-type LT step-down transformers, 5-300 kVA, typically 380-415 VAC 3-phase to 208/120 VAC, wound in pure copper.
5 kVA to 300 kVA (30-150 kW commonly supplied)
Isolation Transformer
1:1 galvanic isolation transformers, 5-300 kVA at 415/415 VAC 3-phase, for solar, UPS and sensitive-load installations.
5 kVA to 300 kVA (10-100 kVA commonly supplied)
DC Distribution Board (DCDB)
Compartmentalised DC distribution boards with per-circuit MCBs, monitoring and earth-fault detection, up to 20 outgoing ways.
24 / 48 / 110 / 220 VDC
not listed

A rating outside these builds

Send the input supply, required output, enclosure rating and site ambient. We quote against the same platform as the listed builds.