Industrial Manufacturing

manufacturing delivery25 products
requirements · 25

What this sector arrives with

copynot yet written

Two distinct problems and the page should separate them: process power (plating, anodising, hydrogenation — high-current DC that is undersized or failing) and supply quality (an unstable incoming supply tripping machinery). The widest sector in the catalogue and the least coherent.

categories serving this industry · 07counts are products serving this industry
Products for this industry · 25ratings are standard builds · pricing by enquiry
Automatic Plating Rectifier
Thyristor-controlled, closed-loop DC supply for electroplating lines — low-voltage, very high current, with optional periodic reverse.
0–60 VDC · 100–20,000 A
Industrial Process Rectifier / High-Current DC Power Supply
SCR-controlled DC power for anodising, electropolishing, hydrogenation, electrowinning and research plant — up to 3,000 A at 200 V and 300 A at 350 V.
0–440 VDC · 20–3,000 A
Multi-Voltage DC Power Supply / TR Unit
Bench or wall-mounted variable DC supply covering 0-110 VDC at up to 20 A, for workshops, instrument rooms and multi-voltage field requirements.
0-110 VDC, up to 20 A
Grid Station Battery Charger — Type A (WAPDA P-133:95)
The standard 110 VDC / 220 VDC substation charger, built to WAPDA specification P-133:95 — the governing specification for grid-station DC supply in Pakistan.
110 VDC · 5–200 A
Vehicle & Workshop Battery Charger 12/24 VDC
Workshop charger for 40-200 Ah vehicle batteries, switchable 12 V / 24 V with automatic taper charge.
12 VDC / 24 VDC selectable
Servo-Controlled Automatic Voltage Regulator
Motorised-variac AVR from 500 VA to 300 kVA holding output within ±1-2% against a ±25% input swing, with no added waveform distortion.
380 VAC ±1% to ±2%, 3-phase; 220 VAC ±1-3%, 1-phase
IGBT-Controlled Static AVR
Transformerless-tap static regulator, 2-100 kVA, correcting to ±1% in milliseconds with no moving parts.
2-15 kVA single-phase; 5-100 kVA three-phase
Relay-Controlled Voltage Stabiliser
Economical stepped-tap stabiliser, 300 VA to 8 kVA, with a very wide 90-280 VAC input window for weak distribution networks.
220 VAC regulated
Harmonic Filter
Passive filter delivering a clean sine wave to sensitive electronic loads on distorted supplies.
400 VAC, 25 A
Surge / Spike Filter
Transient surge and spike suppression to industrial and military standards, protecting equipment on switching-prone supplies.
Step-Down Distribution Transformer
Dry-type LT step-down transformers, 5-300 kVA, typically 380-415 VAC 3-phase to 208/120 VAC, wound in pure copper.
5 kVA to 300 kVA (30-150 kW commonly supplied)
Isolation Transformer
1:1 galvanic isolation transformers, 5-300 kVA at 415/415 VAC 3-phase, for solar, UPS and sensitive-load installations.
5 kVA to 300 kVA (10-100 kVA commonly supplied)
Rectifier-Duty Transformer
Heavy-current secondary transformers designed to BSS-171 for rectifier service, 100-750 kVA, feeding stacks up to 20,000 A.
100 kVA to 750 kVA
Control Transformer
Auxiliary supply transformers for LT and HT switchgear panels, wound to panel-builder requirement.
Waterproof Low-Voltage Transformer
Sealed 6 / 12 / 24 / 36 / 48 VAC transformers for underwater lighting and wet-environment low-voltage supplies.
6 / 12 / 24 / 36 / 48 VAC
DC/AC Inverter Panel
Substation inverters converting the station 110/220 VDC battery bus to 230 VAC or 400 VAC 3-phase, 2-20 kVA.
2 kVA to 20 kVA
AC UPS & Parallel-Redundant UPS
Industrial UPS from 2 kVA to 15 kVA, including parallel-redundant configurations for SCADA and critical control.
2 kVA to 15 kVA
SCR Heat Control Panel with HMI
PLC and HMI supervised SCR power controller for electric process heating, with 4-20 mA setpoint and safety interlocks.
30 kW (higher to order)
superseded
AC Distribution Panel
Built-to-order AC distribution boards for industrial and installation supplies, with metering and per-circuit protection.
400/415 VAC 3-phase 50 Hz
Power Factor Improvement (PFI) Panel
Automatic capacitor bank panels with stepped switching to hold target power factor and cut utility penalty charges.
400/415 VAC 3-phase 50 Hz
ATS & Change-Over Panel
Automatic transfer switch and manual change-over panels for mains/generator and dual-feed installations.
400/415 VAC 3-phase 50 Hz
Motor Starter Panel (Star-Delta / DOL)
Star-delta and direct-on-line motor starter panels with overload and phase protection, built to motor rating.
30 HP star-delta (built to motor rating)
System Monitoring Panel
PLC-based supervisory panel aggregating status, alarms and metering from chargers, inverters and distribution into one interface.
superseded
Single-Phase SCR Triggering Board
Board-level single-phase thyristor firing and control card for AC and DC power control applications.
Three-Phase SCR Triggering Board
Board-level three-phase thyristor firing and control card for AC and DC power control applications.
not listed

A rating outside these builds

Send the input supply, required output, enclosure rating and site ambient. We quote against the same platform as the listed builds.

Enquire