Industrial Manufacturing

تصنيع وتسليم25 منتجات
المتطلبات · 25

What this sector arrives with

نصلم يُكتب بعد

Two distinct problems and the page should separate them: process power (plating, anodising, hydrogenation — high-current DC that is undersized or failing) and supply quality (an unstable incoming supply tripping machinery). The widest sector in the catalogue and the least coherent.

الفئات التي تخدم هذا القطاع · 07الأعداد هي المنتجات التي تخدم هذا القطاع
منتجات لهذا القطاع · 25التصنيفات تكوينات قياسية · التسعير عند الطلب
Automatic Plating Rectifier
Thyristor-controlled, closed-loop DC supply for electroplating lines — low-voltage, very high current, with optional periodic reverse.
0–60 VDC · 100–20,000 A
Industrial Process Rectifier / High-Current DC Power Supply
SCR-controlled DC power for anodising, electropolishing, hydrogenation, electrowinning and research plant — up to 3,000 A at 200 V and 300 A at 350 V.
0–440 VDC · 20–3,000 A
Multi-Voltage DC Power Supply / TR Unit
Bench or wall-mounted variable DC supply covering 0-110 VDC at up to 20 A, for workshops, instrument rooms and multi-voltage field requirements.
0-110 VDC, up to 20 A
Grid Station Battery Charger — Type A (WAPDA P-133:95)
The standard 110 VDC / 220 VDC substation charger, built to WAPDA specification P-133:95 — the governing specification for grid-station DC supply in Pakistan.
110 VDC · 5–200 A
Vehicle & Workshop Battery Charger 12/24 VDC
Workshop charger for 40-200 Ah vehicle batteries, switchable 12 V / 24 V with automatic taper charge.
12 VDC / 24 VDC selectable
Servo-Controlled Automatic Voltage Regulator
Motorised-variac AVR from 500 VA to 300 kVA holding output within ±1-2% against a ±25% input swing, with no added waveform distortion.
380 VAC ±1% to ±2%, 3-phase; 220 VAC ±1-3%, 1-phase
IGBT-Controlled Static AVR
Transformerless-tap static regulator, 2-100 kVA, correcting to ±1% in milliseconds with no moving parts.
2-15 kVA single-phase; 5-100 kVA three-phase
Relay-Controlled Voltage Stabiliser
Economical stepped-tap stabiliser, 300 VA to 8 kVA, with a very wide 90-280 VAC input window for weak distribution networks.
220 VAC regulated
Harmonic Filter
Passive filter delivering a clean sine wave to sensitive electronic loads on distorted supplies.
400 VAC, 25 A
Surge / Spike Filter
Transient surge and spike suppression to industrial and military standards, protecting equipment on switching-prone supplies.
Step-Down Distribution Transformer
Dry-type LT step-down transformers, 5-300 kVA, typically 380-415 VAC 3-phase to 208/120 VAC, wound in pure copper.
5 kVA to 300 kVA (30-150 kW commonly supplied)
Isolation Transformer
1:1 galvanic isolation transformers, 5-300 kVA at 415/415 VAC 3-phase, for solar, UPS and sensitive-load installations.
5 kVA to 300 kVA (10-100 kVA commonly supplied)
Rectifier-Duty Transformer
Heavy-current secondary transformers designed to BSS-171 for rectifier service, 100-750 kVA, feeding stacks up to 20,000 A.
100 kVA to 750 kVA
Control Transformer
Auxiliary supply transformers for LT and HT switchgear panels, wound to panel-builder requirement.
Waterproof Low-Voltage Transformer
Sealed 6 / 12 / 24 / 36 / 48 VAC transformers for underwater lighting and wet-environment low-voltage supplies.
6 / 12 / 24 / 36 / 48 VAC
DC/AC Inverter Panel
Substation inverters converting the station 110/220 VDC battery bus to 230 VAC or 400 VAC 3-phase, 2-20 kVA.
2 kVA to 20 kVA
AC UPS & Parallel-Redundant UPS
Industrial UPS from 2 kVA to 15 kVA, including parallel-redundant configurations for SCADA and critical control.
2 kVA to 15 kVA
SCR Heat Control Panel with HMI
PLC and HMI supervised SCR power controller for electric process heating, with 4-20 mA setpoint and safety interlocks.
30 kW (higher to order)
متوقّف
AC Distribution Panel
Built-to-order AC distribution boards for industrial and installation supplies, with metering and per-circuit protection.
400/415 VAC 3-phase 50 Hz
Power Factor Improvement (PFI) Panel
Automatic capacitor bank panels with stepped switching to hold target power factor and cut utility penalty charges.
400/415 VAC 3-phase 50 Hz
ATS & Change-Over Panel
Automatic transfer switch and manual change-over panels for mains/generator and dual-feed installations.
400/415 VAC 3-phase 50 Hz
Motor Starter Panel (Star-Delta / DOL)
Star-delta and direct-on-line motor starter panels with overload and phase protection, built to motor rating.
30 HP star-delta (built to motor rating)
System Monitoring Panel
PLC-based supervisory panel aggregating status, alarms and metering from chargers, inverters and distribution into one interface.
متوقّف
Single-Phase SCR Triggering Board
Board-level single-phase thyristor firing and control card for AC and DC power control applications.
Three-Phase SCR Triggering Board
Board-level three-phase thyristor firing and control card for AC and DC power control applications.
غير مُدرج

تصنيف خارج هذه التكوينات

أرسل جهد التغذية والخرج المطلوب ودرجة حماية الحاوية ودرجة حرارة الموقع. نُسعِّر على المنصة نفسها المستخدمة في التكوينات المُدرجة.

طلب عرض سعر
القطاعات